"AL" on the cable
Look at exposed cable in the basement, attic or garage. Printing like AL or ALUMINUM on the jacket is a strong sign.
Many New Jersey homes built in the late 1960s and early 1970s were wired with aluminum instead of copper. It's not a reason to panic, but it is a reason to check. This guide shows you how to spot it, explains what the CPSC says about the risk and lists the repairs that actually last.
A warm outlet or burning smell needs same-day attention. Stop using it and call.

Check your home's build date first. Aluminum branch wiring was used mainly from 1965 to the mid-1970s. Then look for AL printed on exposed cable, silver-colored wire at devices, and warning signs like warm outlets or flickering lights. The CPSC recommends permanent repairs: copper replacement, COPALUM or AlumiConn connectors.
The build date is your first clue.
According to the U.S. Consumer Product Safety Commission (CPSC), aluminum wire was used in new homes mainly from about 1965 to the mid-1970s, when copper shortages pushed builders to switch. Homes built before 1965 are unlikely to have it.
That window overlaps with a big wave of building across Monmouth and Middlesex County. If your home dates from the late 1960s or early 1970s, it's worth checking, whether you're in Marlboro, Manalapan, Old Bridge or Holmdel.
You can spot several of these without opening anything.
Look at exposed cable in the basement, attic or garage. Printing like AL or ALUMINUM on the jacket is a strong sign.
At an outlet or switch that's been opened, aluminum wire looks dull silver, not copper-colored.
The CPSC identifies this as the main period of use.
Heat at a device is a warning sign with any wiring, and especially with aluminum.
Loose connections can cause flicker on a single circuit.
A connection that has loosened or oxidized may cut out with no clear reason.
Inspectors often write "single-strand aluminum branch wiring."
It comes down to what happens where the wire connects.

The wire runs themselves aren't usually the problem. The trouble is at the connections. Aluminum expands and shrinks more than copper as it heats and cools, and it forms an oxide layer on its surface. Over years, connections can loosen and heat up.
The CPSC states that homes built before 1972 and wired with aluminum are 55 times more likely to have connections reach fire hazard conditions than homes wired with copper.
Note: the large wires that feed a range, dryer or panel are often aluminum in many homes and are designed for it. The concern is the smaller 15 and 20 amp branch circuits.
Not all fixes are equal. The CPSC is clear about which ones last.
| Method | CPSC view |
|---|---|
| Replace the aluminum branch wiring with copper | Permanent repair |
| COPALUM crimp connectors, installed by trained electricians | Permanent repair |
| AlumiConn connectors | Acceptable alternative permanent repair |
| Twist-on wire connectors | Temporary only |
| CO/ALR outlets and switches | Temporary only |
An electrician joins a short copper wire to each aluminum wire at every outlet, switch, fixture and splice, using a recommended connector. Then devices connect to the copper.
Our aluminum wiring repair page explains how we handle it, and whole house rewiring covers full copper replacement.
Paperwork makes a big difference.
Pair the check with a full electrical safety inspection to see the panel, grounding and other items too. Selling soon? Also read NJ Smoke Detector Certificate: What Sellers Need to Know.
Plain-English answers to the questions homeowners ask us most.
Our licensed electricians serve Marlboro and these nearby towns.
View All Service AreasLook for AL or ALUMINUM printed on exposed cable, and check whether your home was built between about 1965 and the mid-1970s. An electrician can confirm it.
The CPSC says pre-1972 homes with aluminum wiring are 55 times more likely to have connections reach fire hazard conditions than copper-wired homes. Proper repairs greatly reduce that risk.
The CPSC considers CO/ALR devices a temporary repair, not a permanent one.
Not always. The CPSC also recognizes COPALUM and AlumiConn connector repairs at every connection.
Large aluminum feeders for ranges, dryers and panels are common and designed for it. The concern is smaller branch circuits.
A licensed electrician can confirm it in a short visit and explain your repair options.